Motor Efficiency⚠ unverified
Electrical / Motors · Motor efficiency from output and input power
Parameters
| Input | Symbol | Unit | Default | Description |
|---|---|---|---|---|
| Pout | Pout | W | 900.0 | Mechanical output power |
| Pin | Pin | W | 1000.0 | Electrical input power |
| Output | Symbol | Unit | Description |
|---|---|---|---|
| efficiency | η | — | Efficiency |
The science & history
Understanding the Parameters
- $P_{out}$ — the useful shaft power, $T\omega$ (see Motor Power).
-
$P_{in}$ — the electrical power supplied, $VI$ for DC or $\sqrt3\,V_L I_L\,\mathrm{pf}$ for three‑phase (see Watt's Law, Three-Phase Power).
-
$\eta$ — the fraction converted to useful work; $1-\eta$ is lost.
Derivation (Approaching a Proof)
Efficiency is a direct application of energy conservation: input power splits into useful output plus losses,
$$P_{in} = P_{out} + P_{loss} \quad\Rightarrow\quad \eta = \frac{P_{out}}{P_{in}} = \frac{P_{out}}{P_{out} + P_{loss}}.$$
The losses have distinct physical origins: copper loss ($I^2R$ in the windings, rising with load), iron loss (hysteresis + eddy currents in the core, roughly constant with load), and mechanical loss (friction and windage). Because copper loss grows with load while iron loss does not, efficiency peaks at a partial load where the two are comparable, then falls off — the shape captured empirically by an Efficiency Map.
History
Efficiency accounting dates to the 19th‑century establishment of energy conservation and the mechanical equivalent of heat (Joule). It became a regulated design target in the late 20th century, when minimum‑efficiency standards (e.g. IEC IE classes, NEMA Premium) were imposed on the vast installed base of industrial motors, which consume a large share of global electricity.
Related Concepts: Motor Power, Watt's Law, Efficiency Map, Temperature Rise
Notes: Registry calculator motor-efficiency (unverified). Instantaneous ratio at one operating
point; full characterisation uses an efficiency map over the torque–speed plane.